Sample gas probe for Zone 2 explosive areas, with weather protection and in-situ filter with blowback system. With temperature self-regulating heater and integrated safety filter. For applications with high dust load. The safety filter can be replaced without tools.
Buehler GAS 222.21 Ex2 Sample gas probe
- Versions with Atex and IECEx approval
- Heated probe with shut-off valve, inlet and/or outlet filter and weather hood
- The outlet filter can easily be removed by turning the handle 90°
- The probe body and the area around the screw connection for the heated sample gas line are completely isolated
- Heater self-regulating to approx. 120 °C/248 °F (T3)/70 °C/158 °F (T4) with low temperature alarm
- For dust loads up to 2 g/m³ with outlet filter or > 10 g/m³ with inlet filter
- This probe is suitable for use in explosive areas
Categories: Senzory, Vzorkovací sondy plynu
Description